<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">kpccz</journal-id><journal-title-group><journal-title xml:lang="ru">Комплексные проблемы сердечно-сосудистых заболеваний</journal-title><trans-title-group xml:lang="en"><trans-title>Complex Issues of Cardiovascular Diseases</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2306-1278</issn><issn pub-type="epub">2587-9537</issn><publisher><publisher-name>Federal State Budgetary Institution “Research Institute for Complex Issues of Cardiovascular Diseases”</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.17802/2306-1278-2016-2-39-45</article-id><article-id custom-type="elpub" pub-id-type="custom">kpccz-188</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ФУНДАМЕНТАЛЬНЫЕ АСПЕКТЫ КАРДИОЛОГИИ И СЕРДЕЧНО-СОСУДИСТОЙ ХИРУРГИИ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>FUNDAMENTAL ASPECTS OF CARDIOLOGY AND CARDIOVASCULAR SURGERY</subject></subj-group></article-categories><title-group><article-title>ИССЛЕДОВАНИЕ ГИДРОДИНАМИЧЕСКОЙ ФУНКЦИИ МАЛОИНВАЗИВНОГО БИОПРОТЕЗА КЛАПАНА АОРТЫ</article-title><trans-title-group xml:lang="en"><trans-title>INVESTIGATION OF THE HYDRODYNAMIC PERFORMANCE OF THE MINIMALLY INVASIVE AORTIC VALVE PROSTHESIS</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Овчаренко</surname><given-names>Е. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Ovcharenko</surname><given-names>E. A.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Клышников</surname><given-names>К. Ю.</given-names></name><name name-style="western" xml:lang="en"><surname>Klyshnikov</surname><given-names>K. U.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Адрес: 650002, г. Кемерово, Сосновый бульвар, 6 Тел. 8 (3842) 64-45-27</p></bio><bio xml:lang="en"><p>Address: 6, Sosnoviy blvd., Kemerovo, 650002, Russian Federation Tel. +7 (3842) 64-45-27</p></bio><email xlink:type="simple">klyshnikovk@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Саврасов</surname><given-names>Г. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Savrasov</surname><given-names>G. V.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Глушкова</surname><given-names>Т. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Glushkova</surname><given-names>T. V.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Барбараш</surname><given-names>Л. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Barbarash</surname><given-names>L. S.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru">Федеральное государственное бюджетное научное учреждение «Научно-исследовательский институт комплексных проблем сердечно сосудистых заболеваний». Кемерово, Россия<country>Россия</country></aff><aff xml:lang="en">Research Institute for Complex Issues of Cardiovascular Diseases. Kemerovo, Russia<country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru">Московский государственный технический университет имени Н. Э. Баумана. Москва, Россия<country>Россия</country></aff><aff xml:lang="en">Bauman Moscow State Technical University. Moscow, Russia<country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2016</year></pub-date><pub-date pub-type="epub"><day>26</day><month>06</month><year>2016</year></pub-date><volume>0</volume><issue>2</issue><fpage>39</fpage><lpage>45</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Овчаренко Е.А., Клышников К.Ю., Саврасов Г.В., Глушкова Т.В., Барбараш Л.С., 2016</copyright-statement><copyright-year>2016</copyright-year><copyright-holder xml:lang="ru">Овчаренко Е.А., Клышников К.Ю., Саврасов Г.В., Глушкова Т.В., Барбараш Л.С.</copyright-holder><copyright-holder xml:lang="en">Ovcharenko E.A., Klyshnikov K.U., Savrasov G.V., Glushkova T.V., Barbarash L.S.</copyright-holder><license license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.nii-kpssz.com/jour/article/view/188">https://www.nii-kpssz.com/jour/article/view/188</self-uri><abstract><p>Исследование демонстрирует возможность изготовления транскатетерного протеза клапана аорты с последующей оценкой гидродинамической функции в условиях имитации физиологического потока.</p><sec><title>Материалы и методы</title><p>Материалы и методы. В настоящей работе использовали модель самораскрывающегося транскатетерного клапана, полученного на основании предыдущих исследований. Физическую модель протеза изготавливали методом высокоточной лазерной резки трубки из никелида титана сплава SE508 с дальнейшим приданием конечной формы изделия и контролем температуры фазовых превращений с использованием дифференциального сканирующего калориметра (DSC). На изготовленный опорный каркас были монтированы створки и обшивка, выполненные из ксеноперикардиального лоскута, стабилизированного диглицидиловым эфиром этиленгликоля. Исследование в пульс-дупликаторе Vivitro-Systems (Vivitro Labs inc., Канада) было выполнено в условиях имитации физиологического режима работы сердца: минутный объем – 5 л/мин, частота сердечных сокращений – 70 уд/мин, среднее давление в аорте – 100 мм рт. ст., относительная длительность систолического сокращения – 35 %.</p></sec><sec><title>Результаты</title><p>Результаты. Оценка эффективной площади отверстия, являющейся интегральным показателем функции протеза, продемонстрировала преимущество разработанного прототипа: 1,43±0,02 см² против 1,32±0,01 см² контрольного образца (больше на 8 %, p=0,21). Показатели фракции регургитации, представляющие собой совокупные данные трансвальвулярной и паравальвулярной утечек, для прототипа составили 5,08±1,06 %, объем утечки составил 2,40±0,78 мл, а запирающий объем 1,67±0,15 мл. Аналогичные показатели для контрольного образца существенно не различались: 3,66±0,81 %, 1,28±0,51 мл и 1,57±0,12 мл соответственно (р=0,19; р&lt;0,1; р=0,56).</p></sec><sec><title>Заключение</title><p>Заключение. Настоящая работа демонстрирует практическую возможность изготовления прототипа транскатетерного биопротеза клапана аорты на основе каркаса из никелида титана, имеющего гидродинамические показатели, сопоставимые с используемыми в клинике биопротезами с бесшовным способом фиксации. Тем не менее оценка возможности прикладного клинического применения выбранной конструкции требует дальнейших исследований в области циклостойкости, биологической совместимости и углубленного изучения в in vivo экспериментах, полученные результаты и использованные методы оценки могут быть полезны в создании новых транскатетерных биопротезов клапанов сердца.</p></sec></abstract><trans-abstract xml:lang="en"><sec><title>Purpose</title><p>Purpose. The article is to demonstrate the possibility of manufacturing a prototype of transcatheter aortic valve prosthesis, followed by evaluation of its hydrodynamic performance under conditions simulating physiological blood flow.</p></sec><sec><title>Materials and methods</title><p>Materials and methods. In this paper we used the model of self-expanding transcatheter valve obtained on the basis of previous studies. The physical model of the prosthesis are made by high-precision laser cutting of tubes SE508 nickel-titanium alloy (Nitinol) with a further shape training under the control of differential scanning calorimeter (DSC). On the support frame were mounted xenopericardial leaflets stabilized with ethylene glycol diglycidyl ether (EGDE). Thus it was produced a working prototype of self-expanding aortic valve prosthesis. Research was performed in the pulse duplicator Vivitro-Systems (Vivitro Labs inc, Canada) while simulating the physiological mode of heart function: cardiac output of 5 L/min, the frequency of 70 beats/min, the average pressure heart rate in the aorta 100 mmHg, systolic contraction relative duration of 35 %.</p></sec><sec><title>Results</title><p>Results. The prototype of the transcatheter bioprosthesis showed the average value of the transprosthesis pressure gradient 18.01±0.55 mmHg, vs. 19.72±0.16 mmHg – for control (3F Enable, Medtronic Inc, USA) (p=0.37). Also, the prototype demonstrated lower transvalvular flow: the average value 253.62±3.88 ml/s vs. 272.3 1.18 ml/s (control, p=0.29). The regurgitation fraction, calculated as paravalvular and transvalvular leaks for the prototype was 5.08±1.06 %, the amount of leakage was 2.40±0.78 ml, and the closing volume was 1.67±0.15 ml. Similar rates were not significantly different to the control sample: 3.66±0.81 %; 1.28±0.51 ml and 1.57±0.12 ml, respectively (p=0.19; p&lt;0.1; p=0.56).</p></sec><sec><title>Conclusion</title><p>Conclusion. This work demonstrates the feasibility of manufacturing the prototype of transcatheter aortic valve prosthesis with Nitinol frame, having hydrodynamic performance, comparable to those used in clinical bioprostheses with seamless method of fixation. However, the evaluation of the possibility of clinical application of applied chosen design requires further research in durability, biocompatibility, and its in-depth study in vivo experiments, but the results and evaluation methods used may be useful in creating new transcatheter heart valve bioprosthesis.</p></sec></trans-abstract><kwd-group xml:lang="ru"><kwd>ранскатетерный протез</kwd><kwd>гидродинамика</kwd><kwd>физико-механические характеристики</kwd><kwd>кримпирование</kwd><kwd>поток</kwd></kwd-group><kwd-group xml:lang="en"><kwd>TAVI</kwd><kwd>hydrodinamics</kwd><kwd>mechanical properties</kwd><kwd>crimp</kwd><kwd>flow</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Lefèvre T., Kappetein A. P., Wolner E., Nataf P., Thomas M., Schächinger V. et al. PARTNER EU Investigator Group. One year follow-up of the multi-centre European PARTNER transcatheter heart valve study. Eur. Heart. J. 2011; 32 (2): 148–157. DOI: 10.1093/eurheartj/ehq427.</mixed-citation><mixed-citation xml:lang="en">Lefèvre T., Kappetein A. P., Wolner E., Nataf P., Thomas M., Schächinger V. et al. PARTNER EU Investigator Group. One year follow-up of the multi-centre European PARTNER transcatheter heart valve study. Eur. Heart. J. 2011; 32 (2): 148–157. DOI: 10.1093/eurheartj/ehq427.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Piazza N., Grube E., Gerckens U., den Heijer P., Linke A., Luha O. et al. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention. 2008; 4 (2): 242–249.</mixed-citation><mixed-citation xml:lang="en">Piazza N., Grube E., Gerckens U., den Heijer P., Linke A., Luha O. et al. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention. 2008; 4 (2): 242–249.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Bosmans J. M., Kefer J., De Bruyne B., Herijgers P., Dubois C., Legrand V. et al. Belgian TAVI Registry Participants. Procedural, 30-day and one year outcome following CoreValve or Edwards transcatheter aortic valve implantation: results of the Belgian national registry. Interact. Cardiovasc. Thorac. Surg. 2011; 12 (5): 762–767. DOI: 10.1510/ icvts.2010.253773.</mixed-citation><mixed-citation xml:lang="en">Bosmans J. M., Kefer J., De Bruyne B., Herijgers P., Dubois C., Legrand V. et al. Belgian TAVI Registry Participants. Procedural, 30-day and one year outcome following CoreValve or Edwards transcatheter aortic valve implantation: results of the Belgian national registry. Interact. Cardiovasc. Thorac. Surg. 2011; 12 (5): 762–767. DOI: 10.1510/ icvts.2010.253773.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Grube E., Buellesfeld L., Mueller R., Sauren B., Zickmann B., Nair D. et al. Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValve Revalving system. Circ. Cardiovasc. Interv. 2008; 1 (3): 167–175. DOI: 10.1161/CIRCINTERVENTIONS. 108.819839.</mixed-citation><mixed-citation xml:lang="en">Grube E., Buellesfeld L., Mueller R., Sauren B., Zickmann B., Nair D. et al. Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValve Revalving system. Circ. Cardiovasc. Interv. 2008; 1 (3): 167–175. DOI: 10.1161/CIRCINTERVENTIONS. 108.819839.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Weber A., Noureddine H., Englberger L., Dick F., Gahl B., Aymard T. et al. Ten-year comparison of pericardial tissue valves versus mechanical prostheses for aortic valve replacement in patients younger than 60 years of age. J. Thorac. Cardiovasc. Surg. 2012; 144 (5): 1075–1083. DOI: 10.1016/j.jtcvs.2012.01.024.</mixed-citation><mixed-citation xml:lang="en">Weber A., Noureddine H., Englberger L., Dick F., Gahl B., Aymard T. et al. Ten-year comparison of pericardial tissue valves versus mechanical prostheses for aortic valve replacement in patients younger than 60 years of age. J. Thorac. Cardiovasc. Surg. 2012; 144 (5): 1075–1083. DOI: 10.1016/j.jtcvs.2012.01.024.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Исаева И. В., Ковалёва Е. Е., Савелов Е. А., Арабаджян И. С., Крюков В. А., Иоселиани Д. Г. Оригинальный минимально инвазивный ретроперитонеальный доступ к подвздошной артерии для транскатетерной имплантации аортального клапана. Международный журнал интервенционной кардиоангиологии. 2015; 40: 14–20. Isaev I. V., Kovalev E. E., Savelov E. A., Arabajyan I. S., Kryukov V. A., Ioseliani D. G. The original minimally invasive retroperitoneal approach to the iliac artery for transcatheter aortic valve implantation. International Journal of interventional cardiology. 2015; 40: 14–20. [In Russ.].</mixed-citation><mixed-citation xml:lang="en">Исаева И. В., Ковалёва Е. Е., Савелов Е. А., Арабаджян И. С., Крюков В. А., Иоселиани Д. Г. Оригинальный минимально инвазивный ретроперитонеальный доступ к подвздошной артерии для транскатетерной имплантации аортального клапана. Международный журнал интервенционной кардиоангиологии. 2015; 40: 14–20. Isaev I. V., Kovalev E. E., Savelov E. A., Arabajyan I. S., Kryukov V. A., Ioseliani D. G. The original minimally invasive retroperitoneal approach to the iliac artery for transcatheter aortic valve implantation. International Journal of interventional cardiology. 2015; 40: 14–20. [In Russ.].</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Имаев Т. Э., Комлев А. Е., Акчурин Р. С. Транскатетерная имплантация аортального клапана. Состояние проблемы, перспективы в России. Рациональная фармакотерапия в кардиологии. 2015; 1 (11): 53–59. Imaev T. E., Komlev A. E., Akchurin R. S. Transcatheter aortic valve implantation. Status Problems and Prospects in Russia. Rational pharmacotherapy in cardiology. 2015; 1 (11): 53–59. DOI: 10.20996/1819-6446-2015-11-1-53-59. [In Russ.].</mixed-citation><mixed-citation xml:lang="en">Имаев Т. Э., Комлев А. Е., Акчурин Р. С. Транскатетерная имплантация аортального клапана. Состояние проблемы, перспективы в России. Рациональная фармакотерапия в кардиологии. 2015; 1 (11): 53–59. Imaev T. E., Komlev A. E., Akchurin R. S. Transcatheter aortic valve implantation. Status Problems and Prospects in Russia. Rational pharmacotherapy in cardiology. 2015; 1 (11): 53–59. DOI: 10.20996/1819-6446-2015-11-1-53-59. [In Russ.].</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Овчаренко Е. А., Клышников К. Ю., Глушкова Т. В., Нуштаев Д. В., Кудрявцева Ю. А., Саврасов Г. В. Выбор ксеноперикардиального лоскута для створчатого аппарата транскатетерных биопротезов клапанов сердца. Медицинская техника. 2015; 5: 1–4. Ovcharenko E. A., Klyshnikov K. Yu., Glushkova T. V., Nushtaev D. V., Kudryavtseva Yu. A., Savrasov G. V. The choosing of the xenopericardial patch for transcatheter heart valve. Medical equipment. 2015; 5: 1–4. [In Russ.].</mixed-citation><mixed-citation xml:lang="en">Овчаренко Е. А., Клышников К. Ю., Глушкова Т. В., Нуштаев Д. В., Кудрявцева Ю. А., Саврасов Г. В. Выбор ксеноперикардиального лоскута для створчатого аппарата транскатетерных биопротезов клапанов сердца. Медицинская техника. 2015; 5: 1–4. Ovcharenko E. A., Klyshnikov K. Yu., Glushkova T. V., Nushtaev D. V., Kudryavtseva Yu. A., Savrasov G. V. The choosing of the xenopericardial patch for transcatheter heart valve. Medical equipment. 2015; 5: 1–4. [In Russ.].</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Овчаренко Е. А., Клышников К. Ю., Нуштаев Д. В., Саврасов Г. В., Кудрявцева Ю. А., Барбараш Л. С. Исследование геометрии тубулярного створчатого аппарата протеза клапана аорты методом конечных элементов. Биофизика. 2015; 60 (5): 1000–1009. Ovcharenko E. A., Klyshnikov K. Yu., Nushtaev D. V., Savrasov G. V., Kudryavtseva Yu. A., Barbarash L. S. Research of tubular geometry leaflet apparatus of the aortic valve prosthesis via finite element method. Biophysics. 2015; 60 (5): 1000–1009. [In Russ.].</mixed-citation><mixed-citation xml:lang="en">Овчаренко Е. А., Клышников К. Ю., Нуштаев Д. В., Саврасов Г. В., Кудрявцева Ю. А., Барбараш Л. С. Исследование геометрии тубулярного створчатого аппарата протеза клапана аорты методом конечных элементов. Биофизика. 2015; 60 (5): 1000–1009. Ovcharenko E. A., Klyshnikov K. Yu., Nushtaev D. V., Savrasov G. V., Kudryavtseva Yu. A., Barbarash L. S. Research of tubular geometry leaflet apparatus of the aortic valve prosthesis via finite element method. Biophysics. 2015; 60 (5): 1000–1009. [In Russ.].</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Овчаренко Е. А., Клышников К. Ю., Саврасов Г. В., Нуштаев Д. В., Кудрявцева Ю. А. Выбор дизайна каркаса транскатетерного протеза клапана аорты на основе метода конечных элементов. Компьютерные исследования и моделирование. 2015; 7 (4): 909–922. Ovcharenko E. A., Klyshnikov K. Yu., Savrasov G. V., Nushtaev D. V., Kudryavtseva Yu. A. Selecting the design framework of transcatheter aortic valve prosthesis based on the finite element method. Computer studies and modeling. 2015; 7 (4): 909–922. [In Russ.].</mixed-citation><mixed-citation xml:lang="en">Овчаренко Е. А., Клышников К. Ю., Саврасов Г. В., Нуштаев Д. В., Кудрявцева Ю. А. Выбор дизайна каркаса транскатетерного протеза клапана аорты на основе метода конечных элементов. Компьютерные исследования и моделирование. 2015; 7 (4): 909–922. Ovcharenko E. A., Klyshnikov K. Yu., Savrasov G. V., Nushtaev D. V., Kudryavtseva Yu. A. Selecting the design framework of transcatheter aortic valve prosthesis based on the finite element method. Computer studies and modeling. 2015; 7 (4): 909–922. [In Russ.].</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Kalejs M., von Segesser L. K. Rapid prototyping of compliant human aortic roots for assessment of valved stents. Interact. Cardiovasc. Thorac. Surg. 2009; 8 (2): 182–186. DOI: 10.1510/icvts.2008.194134.</mixed-citation><mixed-citation xml:lang="en">Kalejs M., von Segesser L. K. Rapid prototyping of compliant human aortic roots for assessment of valved stents. Interact. Cardiovasc. Thorac. Surg. 2009; 8 (2): 182–186. DOI: 10.1510/icvts.2008.194134.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Ovcharenko E. A., Klyshnikov K. Yu., Vlad A. R., Sizova I. N., Kokov A. N., Nushtaev D. V., Yuzhalin A. E. et al. Computer-aided design of the human aortic root. Comput. Biol. Med. 2014; 54: 109–115. DOI: 10.1016/j.compbiomed. 2014.08.023. [In Russ.].</mixed-citation><mixed-citation xml:lang="en">Ovcharenko E. A., Klyshnikov K. Yu., Vlad A. R., Sizova I. N., Kokov A. N., Nushtaev D. V., Yuzhalin A. E. et al. Computer-aided design of the human aortic root. Comput. Biol. Med. 2014; 54: 109–115. DOI: 10.1016/j.compbiomed. 2014.08.023. [In Russ.].</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Овчаренко Е. А., Клышников К. Ю., Журавлева И. Ю. Зависимость гидродинамических показателей биопротеза «3F Enable» от степени деформации каркаса. Клиническая физиология кровообращения. 2014; 2: 41–47. Ovcharenko E. A., Klyshnikov K. Yu., Zhuravleva I. Yu. The dependence of the hydrodynamic performance of the prosthesis «3F Enable» on the degree of deformation of the frame. Clinical Physiology of blood circulation. 2014; 2: 41–47. [In Russ.].</mixed-citation><mixed-citation xml:lang="en">Овчаренко Е. А., Клышников К. Ю., Журавлева И. Ю. Зависимость гидродинамических показателей биопротеза «3F Enable» от степени деформации каркаса. Клиническая физиология кровообращения. 2014; 2: 41–47. Ovcharenko E. A., Klyshnikov K. Yu., Zhuravleva I. Yu. The dependence of the hydrodynamic performance of the prosthesis «3F Enable» on the degree of deformation of the frame. Clinical Physiology of blood circulation. 2014; 2: 41–47. [In Russ.].</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Folliguet T. A., Laborde F., Zannis K., Ghorayeb G., Haverich A., Shrestha M. Sutureless perceval aortic valve replacement: results of two European centers. Ann. Thorac. Surg. 2012; 93 (5): 1483–1488. DOI: 10.1016/j.athoracsur. 2012.01.071.</mixed-citation><mixed-citation xml:lang="en">Folliguet T. A., Laborde F., Zannis K., Ghorayeb G., Haverich A., Shrestha M. Sutureless perceval aortic valve replacement: results of two European centers. Ann. Thorac. Surg. 2012; 93 (5): 1483–1488. DOI: 10.1016/j.athoracsur. 2012.01.071.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Takagi K., Latib A., Al-Lamee R., Mussardo M., Montorfano M., Maisano F. et al. Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation. Catheter Cardiovasc. Interv. 2011; 78 (3): 432–443. DOI: 10.1002/ccd.23003.</mixed-citation><mixed-citation xml:lang="en">Takagi K., Latib A., Al-Lamee R., Mussardo M., Montorfano M., Maisano F. et al. Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation. Catheter Cardiovasc. Interv. 2011; 78 (3): 432–443. DOI: 10.1002/ccd.23003.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Arri S. S., Poliacikova P., Hildick-Smith D. Percutaneous paravalvular leak closure for symptomatic aortic regurgitation after CoreValve transcatheter aortic valve implantation. Catheter Cardiovasc. Interv. 2015; 85 (4): 657–664. DOI: 10.1002/ccd.25730.</mixed-citation><mixed-citation xml:lang="en">Arri S. S., Poliacikova P., Hildick-Smith D. Percutaneous paravalvular leak closure for symptomatic aortic regurgitation after CoreValve transcatheter aortic valve implantation. Catheter Cardiovasc. Interv. 2015; 85 (4): 657–664. DOI: 10.1002/ccd.25730.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Pibarot P., Garcia D., Dumesnil J. G. Energy loss index in aortic stenosis: from fluid mechanics concept to clinical application. Circulation. 2013; 12; 127 (10): 1101–1104. DOI: 10.1161/CIRCULATIONAHA.113.001130.</mixed-citation><mixed-citation xml:lang="en">Pibarot P., Garcia D., Dumesnil J. G. Energy loss index in aortic stenosis: from fluid mechanics concept to clinical application. Circulation. 2013; 12; 127 (10): 1101–1104. DOI: 10.1161/CIRCULATIONAHA.113.001130.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
