<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">kpccz</journal-id><journal-title-group><journal-title xml:lang="ru">Комплексные проблемы сердечно-сосудистых заболеваний</journal-title><trans-title-group xml:lang="en"><trans-title>Complex Issues of Cardiovascular Diseases</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2306-1278</issn><issn pub-type="epub">2587-9537</issn><publisher><publisher-name>Federal State Budgetary Institution “Research Institute for Complex Issues of Cardiovascular Diseases”</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">kpccz-198</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>В ПОМОЩЬ ПРАКТИЧЕСКОМУ ВРАЧУ</subject></subj-group></article-categories><title-group><article-title>Automatic Internal Cardiac Defibrillator Lead in the Left Ventricle</article-title><trans-title-group xml:lang="en"><trans-title></trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Barbarash</surname><given-names>S.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Address: 888 S Rancho Dr. Las Vegas, NV 89106 Tel. (702) 877-8600</p></bio><email xlink:type="simple">sbarbarash@yahoo.com</email></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Tong</surname><given-names>A.</given-names></name></name-alternatives></contrib></contrib-group><pub-date pub-type="collection"><year>2016</year></pub-date><pub-date pub-type="epub"><day>27</day><month>06</month><year>2016</year></pub-date><volume>0</volume><issue>2</issue><fpage>111</fpage><lpage>114</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Barbarash S., Tong A., 2016</copyright-statement><copyright-year>2016</copyright-year><copyright-holder xml:lang="ru">Barbarash S., Tong A.</copyright-holder><copyright-holder xml:lang="en">Barbarash S., Tong A.</copyright-holder><license license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.nii-kpssz.com/jour/article/view/198">https://www.nii-kpssz.com/jour/article/view/198</self-uri><abstract><sec><title>Introduction</title><p>Introduction: Inadvertent insertion of a pacemaker/defibrillator lead into the left ventricle is an uncommon event, and its actual incidence is probably unknown. It may be underestimated and underreported because of a possible asymptomatic course.</p></sec><sec><title>Case presentation</title><p>Case presentation: We report a case of a 63-year-old Caucasian man with a malpositioned ICD lead into the left ventricle via a subclavian artery that was not suspected during implantation and went undiagnosed for 3 months without complications. The patient remained asymptomatic. He underwent an uncomplicated removal of the device and subsequent placement of a new ICD in the right ventricle.</p></sec><sec><title>Conclusions</title><p>Conclusions: Inadvertent insertion of a pacemaker/defibrillator lead into the left ventricle is a potentially dangerous complication that may occur under fluoroscopic guidance and may be overlooked by routine device interrogation. Careful attention to lead position on CXR posteroanterior and lateral views as well as 12-lead ECG in ventricular paced (magnet mode) after device implantation is recommended.</p></sec></abstract></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Bauersfeld UK, Thakur RK, Ghani M, Yee R, Klein GJ: Malposition of transvenous pacing lead in the left ventricle: radiographic findings. AJR Am J Roentgenol 1994, 162:290– 292.</mixed-citation><mixed-citation xml:lang="en">Bauersfeld UK, Thakur RK, Ghani M, Yee R, Klein GJ: Malposition of transvenous pacing lead in the left ventricle: radiographic findings. AJR Am J Roentgenol 1994, 162:290– 292.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Bollinger BC, Heidenreich J: From cardiac arrhythmias. In Current Diagnosis &amp; Treatment Emergency. 6 edition. Edited by: Stone CK, Humphries RL. New York: Lange Medical Books/McGraw-Hill; 2008:578–607.</mixed-citation><mixed-citation xml:lang="en">Bollinger BC, Heidenreich J: From cardiac arrhythmias. In Current Diagnosis &amp; Treatment Emergency. 6 edition. Edited by: Stone CK, Humphries RL. New York: Lange Medical Books/McGraw-Hill; 2008:578–607.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Schiavone WA, Castle LW, Salcedo E, Graor R: Amaurosis fugax in a patient with a left ventricular endocardial pacemaker. Pacing Clin Electrophysiol 1984, 7:288–292.</mixed-citation><mixed-citation xml:lang="en">Schiavone WA, Castle LW, Salcedo E, Graor R: Amaurosis fugax in a patient with a left ventricular endocardial pacemaker. Pacing Clin Electrophysiol 1984, 7:288–292.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Villanueva FS, Heinsimer JA, Burkman MH, Fananapazir L, Halvorsen RA Jr, Chen JT: Echocardiographic detection of perforation of the cardiac ventricular septum by a permanent pacemaker lead. Am J Cardiol 1987, 59:370–371.</mixed-citation><mixed-citation xml:lang="en">Villanueva FS, Heinsimer JA, Burkman MH, Fananapazir L, Halvorsen RA Jr, Chen JT: Echocardiographic detection of perforation of the cardiac ventricular septum by a permanent pacemaker lead. Am J Cardiol 1987, 59:370–371.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Ormond RS, Rubenfire M, Anbe DT, Drake EH: Radiographic demonstration of myocardial perforation by permanent endocardial pacemakers. Radiology 1971, 98:35–37.</mixed-citation><mixed-citation xml:lang="en">Ormond RS, Rubenfire M, Anbe DT, Drake EH: Radiographic demonstration of myocardial perforation by permanent endocardial pacemakers. Radiology 1971, 98:35–37.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Meyer JA, Millar K: Malplacement of pacemaker catheters in the coronary sinus: recognition and clinical significance. J Thorac Cardiovasc Surg 1969, 57:511–518.</mixed-citation><mixed-citation xml:lang="en">Meyer JA, Millar K: Malplacement of pacemaker catheters in the coronary sinus: recognition and clinical significance. J Thorac Cardiovasc Surg 1969, 57:511–518.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Mazzetti H, Dussaut A, Tentori C, Dussaut E, Lazzari JO: Transarterial permanent pacing of the left ventricle. Pacing Clin Electrophysiol 1990, 13:588–592.</mixed-citation><mixed-citation xml:lang="en">Mazzetti H, Dussaut A, Tentori C, Dussaut E, Lazzari JO: Transarterial permanent pacing of the left ventricle. Pacing Clin Electrophysiol 1990, 13:588–592.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Konings TC, Koolbergen DR, Bouma BJ, Groenink M, Mulder BJ: Iatrogenic Perforation of the posterior mitral valve leaflet: a rare complication pacemaker lead placement. J Am Soc Echocardiogr 2008, 21:512.e5–512.e7.</mixed-citation><mixed-citation xml:lang="en">Konings TC, Koolbergen DR, Bouma BJ, Groenink M, Mulder BJ: Iatrogenic Perforation of the posterior mitral valve leaflet: a rare complication pacemaker lead placement. J Am Soc Echocardiogr 2008, 21:512.e5–512.e7.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Van Erckelens F, Sigmund M, Lambertz H, Kreis A, Reupcke C, Hanrath P: Asymptomatic left ventricular malposition of a transvenous pacemaker lead through a sinus venosus defect: follow-up over 17 years. Pacing Clin Electrophysiol 1991, 14:989–993.</mixed-citation><mixed-citation xml:lang="en">Van Erckelens F, Sigmund M, Lambertz H, Kreis A, Reupcke C, Hanrath P: Asymptomatic left ventricular malposition of a transvenous pacemaker lead through a sinus venosus defect: follow-up over 17 years. Pacing Clin Electrophysiol 1991, 14:989–993.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Van Gelder BM, Bracke FA, Oto A, Yildirir A, Haas PC, Seger JJ, Stainback RF, Botman KJ, Meijer A: Diagnosis and management of inadvertently placed pacing and ICD leads in the left ventricle: a multicenter experience and review of the literature. Pacing Clin Electrophysiol 2000, 23:877–883.</mixed-citation><mixed-citation xml:lang="en">Van Gelder BM, Bracke FA, Oto A, Yildirir A, Haas PC, Seger JJ, Stainback RF, Botman KJ, Meijer A: Diagnosis and management of inadvertently placed pacing and ICD leads in the left ventricle: a multicenter experience and review of the literature. Pacing Clin Electrophysiol 2000, 23:877–883.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
