<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">kpccz</journal-id><journal-title-group><journal-title xml:lang="ru">Комплексные проблемы сердечно-сосудистых заболеваний</journal-title><trans-title-group xml:lang="en"><trans-title>Complex Issues of Cardiovascular Diseases</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2306-1278</issn><issn pub-type="epub">2587-9537</issn><publisher><publisher-name>Federal State Budgetary Institution “Research Institute for Complex Issues of Cardiovascular Diseases”</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.17802/2306-1278-2017-6-3-6-12</article-id><article-id custom-type="elpub" pub-id-type="custom">kpccz-301</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОРИГИНАЛЬНЫЕ ИССЛЕДОВАНИЯ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>ORIGINAL STUDIES</subject></subj-group></article-categories><title-group><article-title>ФУНКЦИОНАЛЬНЫЕ ХАРАКТЕРИСТИКИ БИОПРОТЕЗОВ «ЮНИЛАЙН»</article-title><trans-title-group xml:lang="en"><trans-title>FUNCTIONAL CHARACTERISTICS OF BIOLOGICAL PROTECTION «UNILINE»</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Клышников</surname><given-names>К. Ю.</given-names></name><name name-style="western" xml:lang="en"><surname>Klyshnikov</surname><given-names>K. U.</given-names></name></name-alternatives><bio xml:lang="ru"><p>650002, г. Кемерово, Сосновый бульвар, д. 6</p></bio><bio xml:lang="en"><p>6, Sosnoviy blvd., Kemerovo, 650002</p></bio><email xlink:type="simple">klyshnikovK@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Овчаренко</surname><given-names>Е. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Ovcharenko</surname><given-names>E. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Кемерово</p></bio><bio xml:lang="en"><p>Kemerovo</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Щеглова</surname><given-names>Н. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Scheglova</surname><given-names>N. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Кемерово</p></bio><bio xml:lang="en"><p>Kemerovo</p></bio><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Барбараш</surname><given-names>Л. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Barbarash</surname><given-names>L. S.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Кемерово</p></bio><bio xml:lang="en"><p>Kemerovo</p></bio><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru">Федеральное государственное бюджетное научное учреждение «Научно-исследовательский институт комплексных проблем сердечно-сосудистых заболеваний»<country>Россия</country></aff><aff xml:lang="en">Federal State Budgetary Scientific Institution “Research Institute for Complex Issues of Cardiovascular Diseases”<country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru">ЗАО «НеоКор»<country>Россия</country></aff><aff xml:lang="en">NeoCor LLC<country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2017</year></pub-date><pub-date pub-type="epub"><day>18</day><month>09</month><year>2017</year></pub-date><volume>0</volume><issue>3</issue><fpage>6</fpage><lpage>12</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Клышников К.Ю., Овчаренко Е.А., Щеглова Н.А., Барбараш Л.С., 2017</copyright-statement><copyright-year>2017</copyright-year><copyright-holder xml:lang="ru">Клышников К.Ю., Овчаренко Е.А., Щеглова Н.А., Барбараш Л.С.</copyright-holder><copyright-holder xml:lang="en">Klyshnikov K.U., Ovcharenko E.A., Scheglova N.A., Barbarash L.S.</copyright-holder><license license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.nii-kpssz.com/jour/article/view/301">https://www.nii-kpssz.com/jour/article/view/301</self-uri><abstract><p>Целью работы явилась оценка гидродинамических характеристик биопротезов клапана сердца «ЮниЛайн», предназначенных для протезирования клапана аорты.</p><sec><title>Материалы и методы</title><p>Материалы и методы. В исследовании использовали три биопротеза «ЮниЛайн» (ЗАО «НеоКор», Россия) типоразмером 21, 23, 25 мм, предназначенных для клинического применения. Оценку гидродинамических параметров проводили в установке пульсирующего потока Vivitro (Vivitro Labs, Канада), имитирующей работу «левой» половины сердца. Оценку гидродинамической функции всех протезов осуществляли при создании физиологического режима работы установки – ударный объем = 70 мл; минутный объем = 5 л/мин; среднее давление в камере, имитирующей аорту = 100 мм рт.ст.</p></sec><sec><title>Результаты</title><p>Результаты. Средний транспротезный градиент составил 5,4-15,5 мм рт. ст.; максимальный транспротезный градиент составил 11,9-25,2 мм рт.ст.; эффективная площадь отверстия 1,38-2,15 см2; фракция регургитации 1,5-3,905%; индекс производительности, рассчитанный по посадочному диаметру проходного отверстия протеза = 47,4-68,5%. Заключение. Биопротезы «ЮниЛайн», предназначенные для аортальной позиции, демонстрируют удовлетворительные гидродинамические in vitro показатели, сопоставимые с существующими мировыми аналогами, в то же время, существующая конструкция биопротеза обладает потенциалом углубленной оптимизации створчатого аппарата. </p></sec></abstract><trans-abstract xml:lang="en"><p>The aim of the work was to evaluate the hydrodynamic characteristics of the heart valve bioprosthesis «UniLine», intended for prosthetics of the aortic valve.</p><sec><title>Materials and methods</title><p>Materials and methods. In the contest three prostheses «UniLine» with a size of 21, 23, 25 mm, intended for clinical use. The evaluation of the hydrodynamic parameters was carried out in a Vivitro pulsating flow setup (Vivitro Labs, Canada) simulating the operation of the «left» half of the heart. Estimated hydrodynamic function of all prostheses when creating the physiological mode of operation of the unit - impact volume = 70 ml, minute volume = 5 l/min, mean aortic pressure = 100 mmHg.</p></sec><sec><title>Results</title><p>Results. The average trans-prosthetic gradient was 5,4-15,5 mmHg.; the maximum trans-prosthetic gradient was 11,9-25,2 mmHg; effective orifice area 1,38-2,15 cm2; regurgitation fraction 1,5-3,905%; productivity index, calculated from the inner orifice diameter 47,4-68,5%.</p></sec><sec><title>Conclusion</title><p>Conclusion. Bioprostheses «UniLine», intended for aortic position, demonstrated satisfactory hydrodynamic in vitro characteristics, comparable with existing world analogues. The existing design has the potential to increase hydrodynamic efficiency, but requires advanced approaches and methods, such as FSI, for its implementation. </p></sec></trans-abstract><kwd-group xml:lang="ru"><kwd>протез клапана сердца</kwd><kwd>гидродинамика</kwd><kwd>аортальный клапан</kwd><kwd>транспротезный градиент</kwd><kwd>регургитация</kwd></kwd-group><kwd-group xml:lang="en"><kwd>Heart valve prosthesis</kwd><kwd>hydrodynamics</kwd><kwd>aortic valve</kwd><kwd>trans-prosthetic gradient</kwd><kwd>regurgitation</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Бокерия Л.А., Гудкова Р.Г. Сердечно-сосудистая хирургия – 2015. Болезни и врожденные аномалии системы кровообращения. М.: НЦССХ им. А.Н. Бакулева; 2016. Bokeria L.A., Gudkova R.G. Cardiovascular surgery - 2015. Diseases and congenital anomalies of the circulatory system. M .: NTSSSH them. A.N. Bakuleva; 2016. [In Russ].</mixed-citation><mixed-citation xml:lang="en">Бокерия Л.А., Гудкова Р.Г. Сердечно-сосудистая хирургия – 2015. Болезни и врожденные аномалии системы кровообращения. М.: НЦССХ им. А.Н. Бакулева; 2016. Bokeria L.A., Gudkova R.G. Cardiovascular surgery - 2015. Diseases and congenital anomalies of the circulatory system. M .: NTSSSH them. A.N. Bakuleva; 2016. [In Russ].</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Vesey J.M., Otto C.M. Complications of prosthetic heart valves. Curr Cardiol Rep. 2004; 6(2):106-11. PMID: 14759353.</mixed-citation><mixed-citation xml:lang="en">Vesey J.M., Otto C.M. Complications of prosthetic heart valves. Curr Cardiol Rep. 2004; 6(2):106-11. PMID: 14759353.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Seiler C. Management and follow up of prosthetic heart valves. Heart. 2004; 90(7):818-824. doi:10.1136/hrt.2003.025049.</mixed-citation><mixed-citation xml:lang="en">Seiler C. Management and follow up of prosthetic heart valves. Heart. 2004; 90(7):818-824. doi:10.1136/hrt.2003.025049.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Кудрявцева Ю.А., Насонова М.В., Глушкова Т.В., Акентьева Т.Н., Бураго А.Ю. Сравнительный анализ биоматериала, потенциально пригодного для создания протеза аортального клапана сердца для транскатетерной имплантации. Сибирский медицинский журнал (Иркутск). 2013; 120(50): 66-69. Kudryavtseva Y. A., Nasonova M. V., Glushkova T. V. , Akentieva T. N., Burago A. Yu. Comparative analysis of the biological material potentially suitable for the creation of the aortic heart valve prosthesis for transcatheter implantation. Siberian Medical Journal (Irkutsk). 2013; 120(50): 66-69. [in Russ].</mixed-citation><mixed-citation xml:lang="en">Кудрявцева Ю.А., Насонова М.В., Глушкова Т.В., Акентьева Т.Н., Бураго А.Ю. Сравнительный анализ биоматериала, потенциально пригодного для создания протеза аортального клапана сердца для транскатетерной имплантации. Сибирский медицинский журнал (Иркутск). 2013; 120(50): 66-69. Kudryavtseva Y. A., Nasonova M. V., Glushkova T. V. , Akentieva T. N., Burago A. Yu. Comparative analysis of the biological material potentially suitable for the creation of the aortic heart valve prosthesis for transcatheter implantation. Siberian Medical Journal (Irkutsk). 2013; 120(50): 66-69. [in Russ].</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Караськов А.М., Журавлева И.Ю., Астапов Д.А., Стасев А.Н., Демидов Д.П., Одаренко Ю.Н., Барбараш Л.С. Клинико-гемодинамические результаты применения биопротезов «ЮниЛайн» в аортальной позиции. Кардиология и сердечно-сосудистая хирургия. 2014; 7(4): 87-91. Karaskov A.M., Zhuravleva I.Yu., Astapov D.A., Stasev A.N., Demidov D.P., Odarenko Yu.N., Barbarash L.S. Clinico-hemodynamic results of using bioprostheses uniline in the aortic position. Cardiology and cardiovascular surgery. 2014; 7(4): 87-91. [In Russ].</mixed-citation><mixed-citation xml:lang="en">Караськов А.М., Журавлева И.Ю., Астапов Д.А., Стасев А.Н., Демидов Д.П., Одаренко Ю.Н., Барбараш Л.С. Клинико-гемодинамические результаты применения биопротезов «ЮниЛайн» в аортальной позиции. Кардиология и сердечно-сосудистая хирургия. 2014; 7(4): 87-91. Karaskov A.M., Zhuravleva I.Yu., Astapov D.A., Stasev A.N., Demidov D.P., Odarenko Yu.N., Barbarash L.S. Clinico-hemodynamic results of using bioprostheses uniline in the aortic position. Cardiology and cardiovascular surgery. 2014; 7(4): 87-91. [In Russ].</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Журавлева И.Ю., Кудрявцева Ю.А., Климов И.А., Барбараш Л.С. Сравнительная оценка сшивающей активности новых консервантов из класса эпоксисоединений. Вестник трансплантологии и искусственных органов. 2007; 9(2): 44-48. Zhuravleva I.Yu., Kudryavtseva Yu.A., Klimov I.A., Barbarash L.S. Comparative evaluation of the crosslinking activity of new preservatives from the class of epoxy compounds. Bulletin of transplantology and artificial organs. 2007; 9(2): 44-48. [In Russ].</mixed-citation><mixed-citation xml:lang="en">Журавлева И.Ю., Кудрявцева Ю.А., Климов И.А., Барбараш Л.С. Сравнительная оценка сшивающей активности новых консервантов из класса эпоксисоединений. Вестник трансплантологии и искусственных органов. 2007; 9(2): 44-48. Zhuravleva I.Yu., Kudryavtseva Yu.A., Klimov I.A., Barbarash L.S. Comparative evaluation of the crosslinking activity of new preservatives from the class of epoxy compounds. Bulletin of transplantology and artificial organs. 2007; 9(2): 44-48. [In Russ].</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Бокерия Л.А., Николаев Д.А., Божедомова Е.П., Фадеев А.А. Влияние методики расчета на in vitro оценку эффективной площади проходного отверстия протезов клапанов сердца. Бюллетень НЦССХ им. А.Н. Бакулева РАМН сердечно-сосудистые заболевания. 2013; 14(2): 21-26. Bokeria L.A., Nikolaev D.A., Bozhedomova E.P., Fadeev A.A. Influence of the in vitro calculation technique on the evaluation of the effective area of the opening of the prosthesis of the heart valves. Bulletin of the Center A.N. Bakulev RAMS cardiovascular diseases. 2013; 14 (2): 21-26. [In Russ].</mixed-citation><mixed-citation xml:lang="en">Бокерия Л.А., Николаев Д.А., Божедомова Е.П., Фадеев А.А. Влияние методики расчета на in vitro оценку эффективной площади проходного отверстия протезов клапанов сердца. Бюллетень НЦССХ им. А.Н. Бакулева РАМН сердечно-сосудистые заболевания. 2013; 14(2): 21-26. Bokeria L.A., Nikolaev D.A., Bozhedomova E.P., Fadeev A.A. Influence of the in vitro calculation technique on the evaluation of the effective area of the opening of the prosthesis of the heart valves. Bulletin of the Center A.N. Bakulev RAMS cardiovascular diseases. 2013; 14 (2): 21-26. [In Russ].</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Клышников К.Ю., Овчаренко Е.А., Мальцев Д.А., Журавлева И.Ю. Сравнительная характеристика гидродинамических показателей биопротезов клапанов сердца «ЮниЛайн» и «ПериКор». Клиническая физиология кровообращения. 2013; 1: 45-51. Klyshnikov K.U., Ovcharenko EA, Maltsev DA, Zhuravleva I.Yu. Comparative characteristics of the hydrodynamic parameters of the bioprosthetic valves of the heart valves «UniLine» and «PeriCor». Clinical physiology of blood circulation. 2013; 1: 45-51. [In Russ].</mixed-citation><mixed-citation xml:lang="en">Клышников К.Ю., Овчаренко Е.А., Мальцев Д.А., Журавлева И.Ю. Сравнительная характеристика гидродинамических показателей биопротезов клапанов сердца «ЮниЛайн» и «ПериКор». Клиническая физиология кровообращения. 2013; 1: 45-51. Klyshnikov K.U., Ovcharenko EA, Maltsev DA, Zhuravleva I.Yu. Comparative characteristics of the hydrodynamic parameters of the bioprosthetic valves of the heart valves «UniLine» and «PeriCor». Clinical physiology of blood circulation. 2013; 1: 45-51. [In Russ].</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Орловский П.П., Гриценко В.В., Юхнев А.Д. и др. Искусственные клапаны сердца. Гидродинамика искусственных клапанов сердца. М.: 2007. Orlovsky P.P., Gritsenko V.V., Yukhnev A.D. Artificial heart valves. Hydrodynamics of artificial heart valves. M .: 2007.[In Russ].</mixed-citation><mixed-citation xml:lang="en">Орловский П.П., Гриценко В.В., Юхнев А.Д. и др. Искусственные клапаны сердца. Гидродинамика искусственных клапанов сердца. М.: 2007. Orlovsky P.P., Gritsenko V.V., Yukhnev A.D. Artificial heart valves. Hydrodynamics of artificial heart valves. M .: 2007.[In Russ].</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Овчаренко Е.А., Клышников К.Ю., Саврасов Г.В., Глушкова Т.В., Барбараш Л.С. Исследование гидродинамической функции малоинвазивного биопротеза клапана аорты. Комплексные проблемы сердечно-сосудистых заболеваний. 2016; 5(2): 39-45. Ovcharenko E.A., Klyshnikov K.Yu., Savrasov G.V., Glushkova T.V., Barbarash L.S. Investigation of the hydrodynamic function of a minimally invasive aortic valve bioprosthesis. Complex problems of cardiovascular diseases. 2016; 5(2): 39-45. [In Russ].</mixed-citation><mixed-citation xml:lang="en">Овчаренко Е.А., Клышников К.Ю., Саврасов Г.В., Глушкова Т.В., Барбараш Л.С. Исследование гидродинамической функции малоинвазивного биопротеза клапана аорты. Комплексные проблемы сердечно-сосудистых заболеваний. 2016; 5(2): 39-45. Ovcharenko E.A., Klyshnikov K.Yu., Savrasov G.V., Glushkova T.V., Barbarash L.S. Investigation of the hydrodynamic function of a minimally invasive aortic valve bioprosthesis. Complex problems of cardiovascular diseases. 2016; 5(2): 39-45. [In Russ].</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Marquez S, Hon RT, Yoganathan AP. Comparative hydrodynamic evaluation of bioprosthetic heart valves. J Heart Valve Dis. 2001; 10(6):802-11.</mixed-citation><mixed-citation xml:lang="en">Marquez S, Hon RT, Yoganathan AP. Comparative hydrodynamic evaluation of bioprosthetic heart valves. J Heart Valve Dis. 2001; 10(6):802-11.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Martin C., Sun W. Fatigue damage of collagenous tissues: experiment, modeling and simulation studies. J Long Term Eff Med Implants. 2015; 25(1-2):55-73.</mixed-citation><mixed-citation xml:lang="en">Martin C., Sun W. Fatigue damage of collagenous tissues: experiment, modeling and simulation studies. J Long Term Eff Med Implants. 2015; 25(1-2):55-73.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Ovcharenko E.A., Klyshnikov K.Y., Glushkova T.V., Kudryavtseva Y.A., Nyshtaev D.V., Savrasov G.V. Xenopericardial graft selection for valve apparatus of transcatheter heart valve bioprosthesis. Biomedical Engineering. 2016; 49(5): 1-5.</mixed-citation><mixed-citation xml:lang="en">Ovcharenko E.A., Klyshnikov K.Y., Glushkova T.V., Kudryavtseva Y.A., Nyshtaev D.V., Savrasov G.V. Xenopericardial graft selection for valve apparatus of transcatheter heart valve bioprosthesis. Biomedical Engineering. 2016; 49(5): 1-5.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Овчаренко Е.А., Клышников К.Ю., Глушкова Т.В., Нуштаев Д.В., Кудрявцева Ю.А., Саврасов Г.В. Выбор ксеноперикардиального лоскута для створчатого аппарата транскатетерных биопротезов клапанов сердца. Медицинская техника. 2015; 5: 1-4. Ovcharenko E.A., Klyshnikov K.U., Glushkova T.V., Nushtaev D.V., Kudryavtseva Y. A., Savrasov G.V. The choosing of the xenopericardial patch for transcatheter heart valve. Medical equipment. 2015; 5: 1-4. [in Russ]</mixed-citation><mixed-citation xml:lang="en">Овчаренко Е.А., Клышников К.Ю., Глушкова Т.В., Нуштаев Д.В., Кудрявцева Ю.А., Саврасов Г.В. Выбор ксеноперикардиального лоскута для створчатого аппарата транскатетерных биопротезов клапанов сердца. Медицинская техника. 2015; 5: 1-4. Ovcharenko E.A., Klyshnikov K.U., Glushkova T.V., Nushtaev D.V., Kudryavtseva Y. A., Savrasov G.V. The choosing of the xenopericardial patch for transcatheter heart valve. Medical equipment. 2015; 5: 1-4. [in Russ]</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Ovcharenko E.A., Klyshnikov K.Yu., Glushkova T.V., Nyshtaev D.V., Kudryavtseva Yu.A., Savrasov G.V. Xenopericardial Graft Selection for Valve Apparatus of Transcatheter Heart Valve Bioprosthesis. Biomedical Engineering. 2016; 49(5): 253-257. doi: 10.1007/s10527-016-9543-0.</mixed-citation><mixed-citation xml:lang="en">Ovcharenko E.A., Klyshnikov K.Yu., Glushkova T.V., Nyshtaev D.V., Kudryavtseva Yu.A., Savrasov G.V. Xenopericardial Graft Selection for Valve Apparatus of Transcatheter Heart Valve Bioprosthesis. Biomedical Engineering. 2016; 49(5): 253-257. doi: 10.1007/s10527-016-9543-0.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Martin C., Sun W. Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties. Biomechanics and modeling in mechanobiology. 2014; 13(4):759-770. doi:10.1007/s10237-013-0532-x.</mixed-citation><mixed-citation xml:lang="en">Martin C., Sun W. Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties. Biomechanics and modeling in mechanobiology. 2014; 13(4):759-770. doi:10.1007/s10237-013-0532-x.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Balachandran K., Sucosky P., Jo H., Yoganathan A. P. Elevated Cyclic Stretch Induces Aortic Valve Calcification in a Bone Morphogenic Protein-Dependent Manner. The American Journal of Pathology. 2010; 177(1):49-57.</mixed-citation><mixed-citation xml:lang="en">Balachandran K., Sucosky P., Jo H., Yoganathan A. P. Elevated Cyclic Stretch Induces Aortic Valve Calcification in a Bone Morphogenic Protein-Dependent Manner. The American Journal of Pathology. 2010; 177(1):49-57.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Караськов А.М., Железнев С.И., Рогулина Н.В., Сапегин А.В., Одаренко Ю.Н., Левадин Ю.В. и др.. Отечественный биологический протез нового поколения «ЮниЛайн» в хирургии митрального порока: первый опыт. Грудная и сердечно-сосудистая хирургия. 2017; 59(2): 98-104. Karas’kov A.M., Zheleznev S.I., Rogulina N.V., Sapegin A.V., Odarenko Yu.N., Levadin Yu.V. et al. Domestic biological prosthesis of the new generation «UniLine» in surgery for mitral malformation: the first experience. Thoracic and cardiovascular surgery. 2017; 59(2): 98-104. [In Russ].</mixed-citation><mixed-citation xml:lang="en">Караськов А.М., Железнев С.И., Рогулина Н.В., Сапегин А.В., Одаренко Ю.Н., Левадин Ю.В. и др.. Отечественный биологический протез нового поколения «ЮниЛайн» в хирургии митрального порока: первый опыт. Грудная и сердечно-сосудистая хирургия. 2017; 59(2): 98-104. Karas’kov A.M., Zheleznev S.I., Rogulina N.V., Sapegin A.V., Odarenko Yu.N., Levadin Yu.V. et al. Domestic biological prosthesis of the new generation «UniLine» in surgery for mitral malformation: the first experience. Thoracic and cardiovascular surgery. 2017; 59(2): 98-104. [In Russ].</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Borazjani I. A review of fluid-structure interaction simulations of prosthetic heart valves. J Long Term Eff Med Implants. 2015; 25(1-2):75-93. PMID: 25955008.</mixed-citation><mixed-citation xml:lang="en">Borazjani I. A review of fluid-structure interaction simulations of prosthetic heart valves. J Long Term Eff Med Implants. 2015; 25(1-2):75-93. PMID: 25955008.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
